Fort Sill NC Plan Set Reduced Amendment 1 6 of 11
Updated
A PDF document (9.8 MB) attached to Fort Sill NC Gravesite Expansion and FCA Deficiencies 920CM3006, from the Department of Veterans Affairs. Due Oct 28, 2026, 12:00 PM (UTC-4).
File name: S06_Fort Sill NC_920CM3006_Plan Set_Reduced_Amend 01_6 of 11.pdf
The full file is for paid members, or buy this bid alone.
Preview
A
A
B
B
C
C
D
D
EXISTING POND
LI402
E
E
LI401
F
F
1 INCH =20 FEET
CONSULTANT
ARCHITECT/ENGINEER OF RECORD
JD Engineering, PC
371 Zimmerman Lane
Hamilton, MT 59840
Drawing Title
STAMP
National Cemetery ENLARGED IRRIGATION PLAN
Administration
Design and
Approved: Project Manager/COR
Construction Service Department
of Veteran Affairs, NCA
Phone: (406) 218 - 9980
Revisions:
VA FORM 08 - 6231
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433
720.491.7559; Sean Fitzpatrick
Date:
U.S. Department
of Veterans Affairs
Phase
Project Title
BID DOCUMENTS
FORT SILL
GRAVESITE EXPANSION AND
CEMETERY FCA IMPROVEMENTS
Building Number
Location
Drawing Number
920CM3006
N/A
Elgin, OK
N/A
POC: Homayoun Kazemipour
Email: [email protected]
Project Number
LI402
Issue Date
Checked
07/01/2026
JS
Drawn
CL
A
A
B
B
C
C
1 INCH = 50 FEET
1 INCH = 50 FEET
1 INCH = 50 FEET
EXISTING POND
D
D
EXISTING POND
F3
F7
C1
F5
E
E
C3
F1
C5
1 INCH = 50 FEET
1 INCH = 50 FEET
1 INCH = 50 FEET
1 INCH = 50 FEET
F
F
CONSULTANT
ARCHITECT/ENGINEER OF RECORD
JD Engineering, PC
371 Zimmerman Lane
Hamilton, MT 59840
Drawing Title
STAMP
National Cemetery ENLARGED CONTROLLER
Administration
LOCATIONS
Design and
Approved: Project Manager/COR
Construction Service Department
of Veteran Affairs, NCA
Phone: (406) 218 - 9980
Revisions:
VA FORM 08 - 6231
56 LOUIS PRIMA DRIVE, SUITE B, COVINGTON, LA 70433
720.491.7559; Sean Fitzpatrick
Date:
U.S. Department
of Veterans Affairs
Phase
Project Title
BID DOCUMENTS
FORT SILL
GRAVESITE EXPANSION AND
CEMETERY FCA IMPROVEMENTS
Building Number
Location
Drawing Number
920CM3006
N/A
Elgin, OK
N/A
POC: Homayoun Kazemipour
Email: [email protected]
Project Number
LI403
Issue Date
Checked
07/01/2026
JS
Drawn
CL
HINGED LID- SEE PLAN VIEW
28 18"
SPUN STEEL LID
5/8" O.D. STEEL ROD
3/8" X 1" STEEL BARS
5/8" O.D. STEEL ROD
3/8"X1" STEEL BARS
(4) DECALS, EVENLY SPACED
AROUND BAND - REFER TO
SPECIFICATIONS FOR FONT, TEXT
SIZE, COLOR & COPY.
FLORAL REGULATIONS TEXT, AS
APPROVED BY CEMETERY
DIRECTOR, SEE DETAIL C1/LI502.
1/4"X2 1/2" SOLID STEEL BAR
BOLT TO SLAB
℄
6.
℄
℄
7"
B
EQ
U
AL
℄
6"
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
MANUAL ISOLATION VALVE
C4
NTS
INSTALL AN 8"X8"X16" SOLID CMU BLOCK AT EACH CORNER OF VALVE BOX
WASHED ROCK SHALL BE INSTALLED FLUSH WITH BOTTOM OF GATE VALVE
4" MIN CLEARANCE BETWEEN VALVE BOX LID AND HIGHEST OBJECT IN BOX
AIR RELEASE VALVE ASSEMBLY
℄
KEYED NOTES
1" BRASS CURB STOP VALVE - SEE SPECIFICATIONS.
1" SCH 80 PVC TOE NIPPLE.
The beginning of the document. Download the full file to read on.
Other documents in this bid
- Bid document
- Attachment 11: Fort Sill NC Plan Set Reduced 9 of 11
- Attachment 12: Fort Sill NC Plan Set Reduced 10 of 11
- Attachment 1: Fort Sill NC Invitation for Bids Statement of Work
- Attachment 2: Fort Sill NC Combined Specifications
- Attachment 3: Fort Sill NC Plan Set Reduced 1 of 11
- Attachment 6: Fort Sill NC Plan Set Reduced 4 of 11
- Attachment 7: Fort Sill NC Plan Set Reduced 5 of 11
- Attachment 9: Fort Sill NC Plan Set Reduced 7 of 11
- Prebid Request for Information Fort Sill Gravesite Expansion and FCA
- Bid document
- Fort Sill NC Plan Set Reduced Amendment 1 of 11