Marrion CorrectSeisDef - Appendix-HAZMAT 1
Updated
A PDF document (13.4 MB) attached to Project Number 657-507, Correct Seismic Deficiencies for Building 14, Marion VAMC, Illinois Construction of New Boiler Plant and Demolition of Existing, from the Department of Veterans Affairs. Due Nov 6, 2026, 1:00 PM (UTC-5).
File name: 657-507_Marrion_CorrectSeisDef - Appendix-HAZMAT 1.pdf
The full file is for paid members, or buy this bid alone.
Preview
Pre-Demolition
Hazardous Materials
Inspection Report
Marion VA Medical Center- Building 14
2401 West Main Street
Marion, Illinois 62959
December 18, 2025 | Report Number: 15257307
Prepared for:
Above Group Inc.
305 East Drive
Suite H
Melbourne, Florida 32904
11600 Lilburn Park Road
St. Louis, Missouri 63146
P (314) 692-8811
Terracon.com
December 18, 2025
Above Group Inc.
305 East Drive
Suite H
Melbourne, Florida 32904
Attn:
Mr. Stephen Kazim
(714) 496-3323
[email protected]
RE:
Pre-Demolition Hazardous Materials Inspection Report
Marion VA Medical Center- Building 14
2401 West Main Street
Marion, Illinois 62959
Terracon Project No. 15257307
Dear Mr. Kazim:
Terracon Consultants, Inc. (Terracon) is pleased to submit this pre-demolition hazardous materials inspection report for asbestos-containing materials (ACMs) and lead-containing paint (LCP) at Building 14 within the Marion Veterans Administration Medical Center (VAMC) in Marion, Illinois, to the Above Group Inc. (Above Group, or the Client) for the above-referenced project. Terracon’s services were performed on November 4 and 5, 2025, at the above-referenced site. This inspection was conducted in accordance with Terracon Proposal No. P15257307 dated September 10, 2025. Asbestos-containing materials (ACMs) were identified in the samples collected from the site. The ACMs identified confirmed testing from previously conducted inspections at the site. Additionally, cementitious piping which was labeled as an asbestos-containing material was identified at the site and inaccessible suspect asbestos-containing materials identified at the site were assumed to contain asbestos until sampled by a licensed asbestos building inspector and analyzed for asbestos content by an accredited laboratory. Please refer to the report for additional details. Lead-containing paint was identified on the site. Please refer to the report for additional details. Terracon appreciates the opportunity to provide services to Above Group, Inc. If you have questions regarding this report, please contact George Jones at (314) 692-5196 or [email protected]. Sincerely,
Terracon Consultants, Inc.
Prepared by:
Reviewed by:
Steve Mack
Steven Mack
Field Supervisor
Brandy Howard, PE(CO), CIH, CSP
Department Manager
Authorized Project Reviewer
Facilities | Environmental | Geotechnical | Materials
1.0
1.1
1.2
2.0
3.0
3.1
3.2
4.0
3.1.1
3.1.2
3.1.3
3.1.4
3.2.1
3.2.2
3.2.3
4.1
The beginning of the document. Download the full file to read on.
Other documents in this bid
- Marion CorrectSeisDef - Appendix - Geotech Report 1
- Marion CorrectSeisDef - Appendix - Geologic Hazards Report 1
- Marion CorrectSeisDef - Appendix - Geotech Report GMHA Seismic Report 1
- Marion CorrectSeisDef - Appendix - SHPO MOA 1
- Bid document
- 657-507 VA Marion SeisDefic Bid Specifications
- Bid document
- Site Visit Roster