Mech MACC Request for Proposals
Updated
A PDF document (216 KB) attached to Building SH50 Replace Water Source Heat Pump, from the Department of the Navy. Due Nov 19, 2026, 3:00 PM (UTC-5).
File name: Mech MACC RFP 27R9004.pdf
The full file is for paid members, or buy this bid alone.
Preview
Building SH50 Replace Water Source Heat Pump
MCB Camp Lejeune, North Carolina
Solicitation No. N40085-27-R-9004
Project No. 25-0063
ROICC CAMP LEJEUNE
POC: Clifton Gaither
[email protected]
ONLY THE FOLLOWING LIST OF CONTRACTORS MAY SUBMIT A PROPOSAL
FOR THIS PROJECT:
N40085-20-D-0076
Mechworks Mechanical Contractors, Inc.
5441 HWY 70
Morehead City, NC 28557
(252) 504-3201
POC: Charlie Morgan
[email protected]
N40085-20-D-0078
R&W Construction Company, Inc.
2646 Richlands Highway
Jacksonville, NC 28540
(910) 455-1830
POC: Chris Bland
[email protected]
10/30/2026
N40085-20-D-0077
North State Mechanical, Inc.
225 Ellis Blvd
Jacksonville, NC 28540
(910) 355-9332
POC: Danielle Menture
[email protected]
Building SH50 Replace Water Source Heat Pump
MCB Camp Lejeune, North Carolina
Solicitation No. N40085-27-R-9004
Project No. 25-0063
GENERAL REQUIREMENTS
NAVFAC Solicitation No.: N40085-27-R-9004
Public Works Project No.: 25-0063
Title: Buildings SH50 and HP259 HVAC Repairs
Contract Completion Date: 180 days after award
Estimated Cost Range: Between $1,000,000 and $5,000,000 Wage Determination: General Decision Number: NC20260010 7/28/2026 Building Liquidated Damages: $488.21 per Calendar Day
Notes: One person may fill the roles of Superintendent, Quality Control Manager, and Safety and Health Officer, if duly qualified for all three positions as defined in the project specification. Special Scheduling:
•
•
•
•
Tenant needs 2 weeks notice before work begins.
Contact the Construction manager and Building tenant 14 days before performing work. SH50: Contractor to install provided spot portable heat pump (Dual mode Environment Control Units) to provide temporary heating and cooling for the space during renovation for conference room, Room 102,104,107, & 111. Route portable heat pump exhaust air through ceiling tile and exhaust in attic space.
HP259: Due to demolition and installation of the main 20-ton air handler and associated condensing unit, work outside the mechanical room must occur outside normal operating hours (weekdays, 0800–1630) to minimize disruption. All power outages must be scheduled for weekends or outside normal working hours and require at least five business days’ advance notice to the Contracting Officer.
Basis for Award: Lowest Price
Proposal Acceptance Period: Building HP256 60 days from receipt of offers and SH50 120 days from