Attachment 10: BOR Pumphouse Report 0005
Updated
A PDF document (687 KB) attached to Slv-Cb Pumping Plant Roof, from the Bureau of Reclamation. Due Nov 16, 2026, 1:00 PM (UTC-7).
File name: Attachment_10_-_BOR_Pumphouse_Report_0005.pdf
The full file is for paid members, or buy this bid alone.
Preview
Asbestos Inspector, LLC
PO Box 991 Salida, CO 81201 719-207-2021
Comprehensive Asbestos Building Materials Survey
Prepared by:
Donald Stephens, State of Colorado Building Inspector #18216 Expires August 8, 2027
Re:
Comprehensive Asbestos Bulk Sampling of a roof.
Location:
16399 Lane 6 N, Mosca, CO 81146
Purpose:
To identify suspect materials in a structure to have a roof replaced.
Inspection Date:
October 28, 2026
Asbestos Inspector, LLC
Susan Storm and Alyssa Franks
BOR Facility Staff
10900 US Hwy 160 East
Alamosa, CO 81101
October 31, 2026
Susan and Alyssa,
This report provides information regarding an asbestos building material survey performed at the pump house building at the San Luis Lakes State Wildlife Area located at 16399 Lane 6 N near Mosca, CO 81146. The sampling was conducted in an effort to determine the asbestos content of suspect materials in the roofing materials prior to its removal and replacement. The 40’ x 50‘ building contains 2000 sf of roofing materials. A repair of 450 sf is present toward the SE part of the roof. Donald Stephens of Asbestos Inspector, LLC is a Certified Asbestos Building Inspector in the State of Colorado and conducted the asbestos sampling.
Eurofins EMLab P & K Laboratory, an independent laboratory accredited by the National Voluntary Accreditation Program (NVLAP) and the American Industrial Hygiene Association (AIHA) analyzed the samples utilizing Polarized Light Microscopy (PLM).
Bulk sampling of suspect building materials was conducted to identify any Asbestos Containing Material (ACM). An ACM is defined by the EPA as a material with an asbestos content of greater than 1% by area. Select bulk samples of suspect building materials were collected throughout the residence. Bulk samples of suspect building materials were collected and analyzed. Description of Suspect Building Materials
The roof is composed of several layers of varying materials including black membrane with coatings, foam insulation panels, and tar paper. There is repair over these materials along the SE edge of the roof that has an additional of rolled asphalt and tar. A white layer was applied in various areas, which was included in all samples. A wood substrate is visible on the underside of the roof from within the building. All sample locations above reached the wood substrate.
Homogenous Areas (HA) are defined by CDPHE Regulation 8 as an area of surfacing, miscellaneous, or thermal insulation system materials that are uniform in color and texture. Suspect ACM building
The beginning of the document. Download the full file to read on.
Other documents in this bid
- Attachment 1: SLV-CB PUMPING PLANT ROOF Statement of Work
- Attachment 3: Davis-Bacon Wage Determination Wage Determination
- Sol
- Sol Amendment 0001
- Attachment 5: SF25 0002
- Attachment 6: SF25A 0002
- Sol Amendment 0002
- Attachment 7: Site Visit Synopsis 0003
- Attachment 9: Amendment 0003 Qs As 0003
- Sol Amendment 0003
- Sol Amendment 0004
- Sol Amendment 0005