Encino Lookout
Overall Tower Height: 59’6”
Face Width at Top: 84”
Section 1
Section Height: 14’10”
Face Width: 190”
Panel Numbers: 1
Panel Type: X-Brace
Panel Height: 156.5”
Leg Size: L4”x4”, 0.34”thick
Diagonal Size and Bolts: L2.5”x2.5”, 0.14” thick, 9x0.75” Base Plate Size and Bolts: 12”x12” 2x0.87”
Base Plate L Bracket: 11.5”x5.5”x4”, 0.4” thick
Bottom Gusset Size and Bolts: 10”x7.5”, 0.2” thick, 6x0.75” Bottom Redundant Horizontal Size and Bolts: L2.5”x2.5”, 0.2” thick, 5x0.75”bolts BRH height: 6”
Girt Size and Bolts: 3”x3”, 0.2” thick, 4x0.75”
Girt Offset: 15”
Section 2
Section Height: 31’1”
Panel Numbers: 2
Panel Type: X-Brace, K-down
Panel Height: 147”, 59.5”
Leg Size: L4”x4”, 0.34”thick
Diagonal Size and Bolts: 1.9”x1.9”, 0.19” thick, 9x0.75” bolts Gusset Size and Bolts: 12.25”x8”, 0.27” thick, 10x0.75” bolts Inner Splice plate: L4”x4”, 0.25” thick
Bottom Redundant Horizontal Size and Bolts: 2”x2”, 0.14” thick, 5x0.75” bolts BRH height: 6”
Girt Size and Bolts: 1.9”x1.9”, 0.13” thick
Girt Offset: 8”
BVR Size and Bolts: 1.9”x1.9”, 0.13” thick, 3x0.75” bolts BVR Height: 83”, 67.75”
Section 3
Section Height: 47’1”
Panel Numbers: 2
Panel Type: K-Up, X-Brace
Panel Height: 60&7/8”, 50&11/16” & 52&1/8”
Leg Size: L3.4”x3.4”, 0.26” thick
Diagonal Size and Bolts: 1.9”x1.9”, 0.13” thick, 9x0.75” bolts Gusset Size and Bolts: 11.75”x8”, 0.27” thick, 10x0.75” bolts Inner Splice Plate: 10”x3.5”x3.5”, 0.28” thick
TRH Size and bolts (at top of k-up): 2.4”x2.4”, 0.13” thick, 5x0.75” bolts, height 0” BRH (in x-brace) Size and Bolts: 1.9”x1.9”, 0.13” thick, 3x0.75” bolts BRH height: 4”
Girt Size and Bolts: L2.4”x2.4”, 0.2” thick
Girt Offset: 12”
BVR Size and Bolts: 1.9”x1.9”, 0.13” thick, 3x0.75” bolts BVR Height: 58&3/8”
Section 4
Section Height: 59’6”
Panel#’s: 2
Panel Type: X-Brace
Panel Height: 78.5”, 76&3/8”
Leg Size: L3”x3”. 0.2” thick
Diagonal Size and Bolts: L2”x2”, 0.13” thick, 5x0.75” bolts Middle horizontal size and bolts: L2.5”x2.5”, 0.23” thick Gusset Size and Bolts: 11.75”x8”, 0.27” thick, 10x0.75” bolts Inner splice plate: L10”x3”x3”, 0.19” thick
Bottom Redundant Horizontal Size and Bolts: L2”x2”, 0.13” thick, 3x0.75” bolts BRH height: 3.5”, 3.5”
Girt Size and Bolts: L2.5”x2.5”, 0.23” thick
Girt Offset: 3”
BVR Size and Bolts: L1.9”x1.9”, 0.13”thick, 2x0.75” bolts BVR Height: 39.5”, 42”
The beginning of the document. Download the full file to read on.
Other documents in this bid
- Bid document
- Attachment 1: Statement of Work
- Attachment 3: Specifications
- Attachment 4: Fire Plan and Guidelines
- Attachment 5: Wage Determination
- Attachment 6: Wage Determination
- Amendment 1: Provisions and Clauses
- Amendment 1
- Bid document
- Attachment 12: Region 3-0310 Santa Fe National Forest - Encino LO
- Attachment 13 -Encino Lookout- 01
- Attachment 14 -Encino Lookout- -Data V1.1