Attachment 17 -Barillas Lookout
Updated
A PDF document (1.8 MB) attached to Barillas Peak & Encino Vista Lookout Tower Restoration, Santa Fe NF, from the Forest Service. Due Nov 16, 2026, 2:00 PM (UTC-8).
File name: C05 Attachment 17 031005L050501-Barillas Lookout-20230906-SAR-V9.pdf
The full file is for paid members, or buy this bid alone.
Preview
Page
Barrillas Lookout Tower
Project
FAA Structural Support
8201 S. MacArthur Boulevard
Oklahoma City, OK 73169
STRUCTURAL ANALYSIS
For
USFS
By
FAA-AJW-L500
FEASIBILITY STRUCTURAL ANALYSIS REPORT
OF
EXISTING STRUCTURE, TECHNOLOGY & OTHER ASSETS
FOR
U.S Forest Service
Tower Location
Region 03, Forest 10
New Mexico – Barillas Lookout
Santa Fe County, California
Latitude: 35°34'7.75"N, Longitude: 105°28'24.13"W
Report Date
Jul-2024
Analysis and Report by:
Mohanad Ashor, EIT
Civil Engineer
FAA Mike Moroney Air Logistics Center
Oklahoma City, Oklahoma
Report Checked by:
Eric Trujillo
Civil Engineer
FAA Mike Moroney Air Logistics Center
Oklahoma City, Oklahoma
Structural Analysis Report | REV 1.1
Page
Barrillas Lookout Tower
Project
FAA Structural Support
8201 S. MacArthur Boulevard
Oklahoma City, OK 73169
For
STRUCTURAL ANALYSIS
USFS
By
FAA-AJW-L500
Structural Analysis Report | REV 1.1
Page
Barrillas Lookout Tower
Project
FAA Structural Support
8201 S. MacArthur Boulevard
Oklahoma City, OK 73169
For
STRUCTURAL ANALYSIS
USFS
By
FAA-AJW-L500
Executive Summary
The analyzed tower is approximately 54.4 feet Self Support Tower constructed of 5 sections supporting existing technology and other assets attached at multiple heights on the tower. The tower is located near Santa Fe County, New Mexico and supports operational and functional capacity of the sector. Tower has been identified for an update of the tower capacity. A full tower assessment has not been completed only the tower mapping and equipment inventory have been analyzed with current field notes which constitute the basis of the tower model and analysis.
All information not collected to complete the structural analysis will be derived from past experience, standard industry practice and other available information. Information not provided for incorporation into the structural analysis report will constitute a limiting factor for the operational (or functional) capacity of the tower structure. Completion of a structural analysis does not constitute a verification of the operational degradation of existing technology, appurtenances, and other assets due to potential increases in deflection tilt or twist of the tower structure.
This information was used to determine the tower rating and safe load capacity for the tower in accordance with the provisions contained in ANSI/TIA-222, “Structural Standard for Antenna Supporting Structures and Antennas”. The tower was modeled with the currently recorded existing loading under the site-specific
The beginning of the document. Download the full file to read on.
Other documents in this bid
- Bid document
- Attachment 1: Statement of Work
- Attachment 3: Specifications
- Attachment 4: Fire Plan and Guidelines
- Attachment 5: Wage Determination
- Attachment 6: Wage Determination
- Amendment 1: Provisions and Clauses
- Amendment 1
- Bid document
- Attachment 11: Encino LO Structural Data
- Attachment 12: Region 3-0310 Santa Fe National Forest - Encino LO
- Attachment 13 -Encino Lookout- 01