DEMOLITION PLAN SYMBOLS
DEMOLITION GENERAL NOTES
DP2
2101AD201
DP12
1. CONTRACTOR MUST COORDINATE ALL DEMOLITION WORK, PHASING AND SEQUENCING WITH THE
OWNER. ANY INFORMATION REGARDING SEQUENCING PROVIDED IN THESE DOCUMENTS IS FOR
ARCHITECT - OWNER PLANNING PURPOSES ONLY, UNLESS NOTED OTHERWISE.
DP12
2. CONTRACTOR MUST BE RESPONSIBLE FOR COORDINATING WITH ALL TRADES FOR THE
DEMOLITION WORK REQUIRED FOR THIS PROJECT.
A
3. WHERE PARTITIONS ARE INDICATED TO BE REMOVED, REMOVE PARTITION ALONG WITH ALL
ITEMS CONTAINED WITHIN, INCLUDING DOORS, FRAMES, HARDWARE, SIDELIGHTS, WINDOWS,
MECHANICAL AND ELECTRICAL EQUIPMENT, ETC. TO STRUCTURE ABOVE, UNLESS NOTED
OTHERWISE.
EXISTING
UNISEX
TOILET
EXISTING
ADMIN
OFFICER
EXISTING
ADMIN
STAFF
DP12
EXISTING
CORRIDOR
DP2
B
EXISTING
STORAGE
WALL OR
PARTITION TO BE
REMOVED
EXISTING DOOR
AND FRAME TO BE
DEMOLISHED
DE10
A
KEY NOTE
REMOVE ALL
STUCCO FROM WALL
AND ENTRANCE
CANOPY IN IT'S
ENTIRETY.
GRIDLINE
AREA OF DEMO
NIC
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
6. WHERE INDICATED, REMOVE ALL WALL/PARTITION EXISTING FINISHES AND PREPARE THE
SURFACES FOR SCHEDULED FINISHES, SEE FINISH SCHEDULE FOR FINISHES.
DP2
7. ALL DISTURBED AREAS, WALLS, PARTITIONS, FLOORS, ETC, DAMAGED BY DEMOLITION WORK MUST BE PATCHED TO MATCH ADJACENT AREA.
DP12
EXISTING
DIRECTOR
A
5. WHERE CEILING IS INDICATED TO BE DEMOLISHED, REMOVE CEILING SUSPENSION SYSTEM
ALONG WITH ALL ASSOCIATED MECHANICAL AND ELECTRICAL ITEMS, UNLESS NOTED OTHERWISE. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF CONDUIT, PIPING AND DUCTWORK DEMOLITION WITHIN AREA TO BE REMODELED. CUT CEILING GRID AND CEILING TILES ONLY TO ALLOW FOR THE CONSTRUCTION OF THE TE ROOM WALLS. WHERE CEILING IS INDICATED TO BE
DEMOLISHED, MODIFY CEILING GRID AND CUT CEILING TILES AS NECESSARY TO ENSURE
ORIGINAL FINISHED CEILING LAYOUT IS MAINTAINED. REINSTALL WALL MOLDING IN ALIGNMENT WITH EXISTING WALL MOLDING, MITER CUT OUTSIDE CORNER, AND PROVIDE STABILIZER CLIPS AS
NECESSARY. REPLACE ALL CEILING TILES DAMAGED OR SOILED DURING THE COURSE OF
CONSTRUCTION WITH NEW TILES TO MATCH EXISTING.
DP12
EXISTING DOOR
AND FRAME TO
REMAIN
DASHED LINE
INDICATES ITEM TO
BE REMOVED (UNO)
4. WHERE FLOOR FINISH IS INDICATED TO BE DEMOLISHED, REMOVE FINISH TO FLOOR SLAB AS
REQUIRED AND PREPARE SLAB SURFACE FOR SCHEDULED FINISHES WITHIN AREA TO BE
REMODELED, UNLESS NOTED OTHERWISE. REMOVE CARPET TILE UP TO THE FACE OF THE NEW TE
ROOM WALLS. PROTECT CARPET FOR REINSTALLATION AS NECESSARY. SEE FINISH SCHEDULE
FOR EXISTING FLOOR FINISHES TO REMAIN UNDISTURBED.
EXISTING
PROGRAM
SPECIALIST
The beginning of the document. Download the full file to read on.
Other documents in this bid
- Fort Bliss Gravesite Expansion BD Part 1
- Fort Bliss Gravesite Expansion BD Part 10
- Fort Bliss Gravesite Expansion BD Part 11
- Fort Bliss Gravesite Expansion BD Part 2
- Fort Bliss Gravesite Expansion BD Part 3
- Fort Bliss Gravesite Expansion BD Part 4
- Fort Bliss Gravesite Expansion BD Part 5
- Fort Bliss Gravesite Expansion BD Part 6
- Fort Bliss Gravesite Expansion BD Part 8
- Fort Bliss Gravesite Expansion BD Part 9
- Fort Bliss Gravesite Expansion - Specifications Full Book
- Solicitation