612A4-27-020
DEPARTMENT OF VETERANS AFFAIRS
VHA MASTER SPECIFICATIONS
Section 00 01 10
SECTION NO
DIVISION AND SECTION TITLES
DATE
DIVISION 00 - SPECIAL SECTIONS
00 01 10
00 01 15
List of Drawings
09-26
09-26
DIVISION 01 - GENERAL REQUIREMENTS
01 00 00
01 33 23
01 35 26
01 42 19
01 74 19
01 81 13
General Requirements
Shop Drawings, Product Data, and Samples
Safety Requirements
Reference Standards
Construction Waste Management
Sustainable Construction Requirements
09-26
11-23
05-24
11-20
04-22
10-17
DIVISION 02 – EXISTING CONDITIONS
02 41 00
02 82 11
02 82 13.19
Demolition
Traditional Asbestos Abatement
Asbestos Floor tile and Mastic Abatement
09-26
09-26
09-26
DIVISION 07 – THERMAL AND MOISTURE PROTECTION
07 84 00
07 92 00
Firestopping
Joint Sealants
09-26
06-26
DIVISION 09 – FINISHES
09 05 16
09 06 00
09 65 13
09 65 19
09 68 00
Subsurface Preparation for Floor Finishes
Schedule for Finishes
Resilient Base and Accessories
Resilient Tile Flooring
Carpeting
00 01 10-1
06-26
06-26
09-26
06-26
06-26
612A4-27-020
09-14-20
SECTION 00 01 15
LIST OF DRAWING SHEETS
The drawings listed below accompanying this specification form a part of the contract.
Drawing No.
BUILDING
Title
VA100
-
COVER SHEET
VA101
ARCHITECTURAL PLAN – BASEMENT (N.I.C.)
VA102A
ARCHITECTURAL PLAN – EXISTING LEVEL 1 FLOORING
VA102B
ARCHITECTURAL PLAN – NEW LEVEL 1 FLOORING
VA103A
ARCHITECTURAL PLAN – EXISTING LEVEL 2 FLOORING
VA103B
ARCHITECTURAL PLAN – NEW LEVEL 2 FLOORING
VA104A
ARCHITECTURAL PLAN – EXISTING BASEMENT FLOORING
VA104B
ARCHITECTURAL PLAN – NEW BASEMENT FLOORING
VA105A
ARCHITECTURAL PLAN – EXISTING LEVEL 1 FLOORING
VA105B
ARCHITECTURAL PLAN – NEW LEVEL 1 FLOORING
VA106A
ARCHITECTURAL PLAN – EXISTING LEVEL 2 FLOORING
VA106B
ARCHITECTURAL PLAN – NEW LEVEL 2 FLOORING
VA107A
ARCHITECTURAL PLAN – EXISTING LEVEL 1 FLOORING
VA107B
ARCHITECTURAL PLAN – NEW LEVEL 1 FLOORING
VA108A
ARCHITECTURAL PLAN – EXISTING LEVEL 2 FLOORING
VA108B
ARCHITECTURAL PLAN – NEW LEVEL 2 FLOORING
VA109A
ARCHITECTURAL PLAN – EXISTING LEVEL 3 FLOORING
VA109B
ARCHITECTURAL PLAN – NEW LEVEL 3 FLOORING
- - - END - - -
00 01 15 - 1
612A4-27-020
SECTION 01 00 00
GENERAL REQUIREMENTS
GENERAL
1.1
SAFETY REQUIREMENTS
A. Refer
to section 01 35 26, SAFETY REQUIREMENTS for safety
and infection control requirements.
1.2
GENERAL INTENTION
A. Contractor
must remove existing flooring, stair treads,
wall bases, and their related accessories and replace with new. Locations of work are per the provided project
drawings for McClellan VA buildings 98, 209 and 949.
The beginning of the document. Download the full file to read on.
Other documents in this bid
- Made in the USA Supply Chain PDF v7 Digital
- PCRA Replace Flooring in McCellan
- MILLWORK WALL FINISHING SYSTEMS
- WALL BASE
- RST RESILIENT STAIR TREADS
- Tarkett Wall Base Made in USA
- Wage Determination dtd 9 3 2026
- Site Visit Flyer
- Price Breakdown Worksheet
- Statement of Work ATTACHMENT Reference Drawings
- Requests for Information Request for Information Form
- Sol