VISN 2 Northport Data Center - Civil SIte Plan
Updated
A PDF document (737 KB) attached to VISN 2 EHRM Industry Day, from the Department of Veterans Affairs. Due Nov 12, 2026, 2:00 PM (UTC-5).
File name: VISN 2 Northport Data Center - Civil SIte Plan.pdf
The full file is for paid members, or buy this bid alone.
Preview
-S
EX
UTILITY KEYED NOTES:
SS
EX
EX-E
-E
SIG
E
EX
-E
X
E
EX
-E
SIG
SIG
SIG
SIG
SIG
SIG
///////////
MH. 12
EL. 136.59
-E
EX
EXE
7-TTTTTTTTTTZ
EX-SS
^/ //// ////////// V
EX-E
EX-SS
o
o
o
EX-E
H
o
o
o
o
EX
A
EX-E
ss
SAS
EX-E
EX-W
6.
TIE NEW 8" LINE INTO EXISTING VALVE WITH NON-RISING STEM.
7.
TIE NEW ROOF DRAIN INTO EXISTING STORM DRAIN.
8.
INSTALL NEW 8" STORM DRAIN LINE WITH RISERS TO SURFACE FOR
ROOF DRAINING.
9.
INSTALL 4" CLEANOUTS AT SURFACE.
X-W
ESAS
EX-W
W-ABD
EX-S
D
EX-W
EX-W
W
MH. 29
FR.FL. 156.00
C
W-ABD
EX-SS
o
o
O
(3
o
o
o
EX-SAS
E
EX-W
///////////
//////////////// h
///////////////
□
SAS
EX-SS
EX-SS
□
r///// ////////// /
SAS
GENERAL NOTES:
1.
EXISTING UTILITIES ARE SHOWN TO THE BEST AVAILABLE
INFORMATION. CONTRACTOR TO VERIFY UTILITY LOCATIONS W/
GPR AND POTHOLING.
2.
WHERE A SEWER LINE CROSSES OR PARALLELS A POTABLE WATER
OR FIRE WATER LINE, SEWER LINE MUST BE CONCRETE ENCASED
FOR TWENTY-FIVE (25') FEET ON EACH SIDE OF THE WATER LINE, OR
AS REQUIRED BY THE AHJ OR THE GOVERNMENT. WATER LINE
SHALL BE SLEEVED WITH LARGER PIPE FOR A MINIMUM OF
TWENTY- FIVE (25') FEET FROM THE CROSSING POINT.
////////////////
EX-W
INSTALL NEW 8" PVC SERVICE LINE TO BUILDING WITH PIV (POST
INDICATOR VALVE) AND FOUR BOLLARDS.
□
o
(3
o
o
o
o
o
SAS
EX-SS
EX-SS
EX-W
D
EX-W
SAS
SAS
EX
-S
S
(3
EX-SS
MH. 13
EL. 138.28
D
EX-SS
XSS
A
////
-W
EX
EX-W
5.
////// nr? //////
EX-SS
INSTALL 8" 22.5 DEGREE ELBOW AND THRUST BLOCKING.
13. INSTALL 354' NEW 8" PVC SANITARY SEWER FROM NEW MANHOLE
TO EXISTING MANHOLE 12.
x
EX-SS
4.
EX-SS
FIN. FLR. 1
@ 160.57'
EX-SS
EX-SS
INSTALL 8" 45 DEGREE ELBOW AND THRUST BLOCKING.
B
EX-SS
EX-SS
UNK
SAS
FIN. FLR. T
@ 155.46'
FUEL TANK
EX-SS
3.
EX-SS
SAS
EX-SS
INSTALL NEW 8" 90 DEGREE ELBOW GATE VALVE AND THRUST
BLOCKING.
SIG
MH. 12A
IE(E) 153.60
IE(S) 153.50
W-ABD
2.
12. INSTALL NEW 4' 0" SANITARY SEWER MANHOLE. MANHOLE 12A
BLDG. 12
NEW DATA CENTER
BLDG. 300
C
INSTALL NEW 8" PVC C-900 WATER LINE.
11. INSTALL NEW 77' 8" PVC SANITARY SEWER FROM BUILDING TO NEW
MANHOLE. MAINTAIN MINIMUM 0.4% SLOPE.
K
EX-SS
EX-COM
SIG
SIG
SIG
B
1.
10. INSTALL NEW 8" PVC STORM DRAIN AND CONNECT TO EXISTING
STORM DRAIN MANHOLE.
///////////////
S
/////////// x
-S
EX
-E
EX
/////!
EX
S
-S
/////// A
A
SIG
EX
//
S
-S
X
E
EX-E
o
/////////////
o
EX-W
EX-SS
o
o
o
o
EX
-S
MH. 13AA S
FR EL. 134.48
BLDG. 11
1" CONDUIT (ELECT)
o
8" PVC (WATER)
EX-W
SAS
BN
SAS
EX-W
SAS
ARCHITECT OF RECORD
SAS
j*1
*
-'^ -3 lvio u?h
A N V d I/M □
VA
a/
A N V d I/M □
L
□
Phone: (210) 816-4784
Fax: (210) 881-6808
8U
8718 Botts Lane
San Antonio, Texas 78217
www.hfscompany.com
IN ^
I
Phone: (210) 816-4784
Fax: (210) 881-6808