BEAM:

SEE PLAN

JOIST:

SEE PLAN

SIMPSON

LUS

HANGER

TYP. JOIST TO BEAM DETAIL

JOIST HANGER, TYP.





JAD

GJC

FASTENERS @12" O.C.

2-PLY

3-PLY

TYP. MULTI-PLY FASTENING DETAIL

JD-001

TYPICAL WOOD PALLETTE

3/4" = 1'1'-0"
0"

NOTE:

REMOVE EXISTING X-BRACING WHERE NEW JOISTS WILL BE INSTALLED. AFTER NEW JOISTS ARE INSTALLED, REINSTALL X-BRACING OR BLOCKING AT THE ORIGINAL X-BRACE LOCATIONS.

SIMPSON TB

SCREWS

SIMPSON TB

SCREWS

BEAM: SEE

PLAN

BEAM: SEE

PLAN

TYPICAL WOOD TO STEEL FASTENING DETAILS

OPENING

2x8 MIN. HEADER

OR MATCH EXIST.

JOISTS

JD-001

< 4'4'-0"

0" OPENING

4'4'-0"

0" < OPNEING <6'-0"

CASE 1

CASE 2

TYPICAL OPENING DETAIL

3/4" = 1'-0"
1'-0"



JOISTS OR

RAFTERS

16 GA. TIES W/

(8) 16d NAILS

MIN. PER

CONN.

JOIST: SEE PLAN

2x_ PLATE NOT WIDER

THAN TUBE FACE

TYP. WOOD TO STEEL BEARING DETAIL

OPENING

4"
MIN.

3"
MIN
.



JOISTS OR

RAFTERS

ADD'L L TRIMMER

TO DOUBLE EXIST.

JOIST (SIZE TO

MATCH EXIST.)

1 1/

2"
MI
N.

SIMPSON WSNTL

SERIES SCREW

POWER ACTUATED

FASTENERS @ 12"

O.C.

PROVIDE BLOCKING WHEN

STEEL BEAM IS DEEPER THAN

WOOD JOIST

4"
MIN
.

COLUMN/BEAM: SEE PLAN

1 1/

2"
MI
N.

2x_ PLATE NOTE

WIDER THAN BEAM

FLANGE

SIMPSON BA

HANGER

2x_ PLATE NOT

WIDER THAN BEAM

FLANGE

.
MIN
"

1 1/

LRC

ADD'L L TRIMMER

TO DOUBLE EXIST.

JOIST (SIZE TO

MATCH EXIST.)

DOUBLE

HEADERS(SIZE TO

MATCH EXIST.

JOISTS)

MAY 04, 2026







TYPICAL WOOD DETAILS







RENOVATE H8

LABORATORY, B3

