Tinker AFB, OK

TAFB Technical Sprcifications 2019

SECTION 06 41 16.00 10

PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS

PART 1

1.1

GENERAL

REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)

ANSI A161.2

(1998) Decorative Laminate Countertops,
Performance Standards for Fabricated High
Pressure

ARCHITECTURAL WOODWORK INSTITUTE (AWI)

AWI AWS

(2nd Edition) Architectural Woodwork
Standards

ASTM INTERNATIONAL (ASTM)

ASTM D1037

(2012) Evaluating Properties of Wood-Base
Fiber and Particle Panel Materials

ASTM E84

(2016) Standard Test Method for Surface
Burning Characteristics of Building
Materials

ASTM F547

(2006; R 2012) Nails for Use with Wood and
Wood-Base Materials

BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)

ANSI/BHMA A156.9

(2015) Cabinet Hardware

COMPOSITE PANEL ASSOCIATION (CPA)

CPA A208.1

(2016) Particleboard

CPA A208.2

(2016) Medium Density Fiberboard (MDF) for
Interior Applications

NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)

ANSI/NEMA LD 3

(2005) Standard for High-Pressure
Decorative Laminates

SCIENTIFIC CERTIFICATION SYSTEMS (SCS)

SCS

April 2019

SCS Global Services (SCS)Indoor Advantage

SECTION 06 41 16.00 10

Tinker AFB, OK

TAFB Technical Sprcifications 2019

U.S. GREEN BUILDING COUNCIL (USGBC)

LEED BD+C

(2009; R 2010) Leadership in Energy and
Environmental Design(tm) Building Design
and Construction (LEED-NC)

UL ENVIRONMENT (ULE)

ULE Greenguard

UL Greenguard Certification Program

WINDOW AND DOOR MANUFACTURERS ASSOCIATION (WDMA)

ANSI/WDMA I.S.1A

1.2

(2013) Interior Architectural Wood Flush
Doors

SYSTEM DESCRIPTION

Work in this section includes laminate clad custom casework cabinets as shown on the drawings and as described in this specification. This Section includes high-pressure laminate surfacing and cabinet hardware. All exposed and semi-exposed surfaces, whose finish is not otherwise noted on the drawings or finish schedule, shall be sanded smooth and shall receive a clear finish of polyurethane. Wood finish may be shop finished or field applied in accordance with Section 09 90 00 PAINTS AND COATINGS. 1.3

SUBMITTALS

Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for Contractor Quality Control approval. Submit the following in accordance with Section 01 33 00

SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

The beginning of the document. Download the full file to read on.