01 CLEAN, PATCH, AND LEVEL CONCRETE SLAB AND COVER WITH
A
A
KEYNOTES
AN APPLICATION OF A PAINTED EPOXY FINISH WITH NON-SLIP
GRIT ADDED. SEE MAINTENANCE GARAGE NOTES.
02 CLEAN AND RESEAL CONCRETE SLAB.
58'-114"
21'-1114"
32'-8"
03 PCC SLAB
04 EXPANSION JOINT
NOTES
B
B
8'-0"
SAWCUT 4"x 4" GROOVE TO BULLNOSE COATING EDGE.
05 COORDINATE
LOCATION WITH THRESHOLD INSTALL.
17'-1"
19'-1"
MAINTENANCE GARAGE FLOOR
1.
CLEAN TO REMOVE ALL SOLUBLE SURFACE CONTAMINANTS.
REMOVE ALL UNSOUND CONCRETE. MECHANICALLY PREPARE TO
REMOVE ALL INSOLUBLE SURFACE CONTAMINANTS AND ACHIEVE
AN ICRI CSP 3. VERIFY MOISTURE LEVELS ARE IN ACCORDANCE
WITH MANUFACTURER'S INSTRUCTIONS.
7'-9"
32'-8"
2.
SURFACE PREPARATION:
COATING SYSTEM:
·
·
·
C
WEATHERPROOF STORAGE, SEE SHEET AE-131.
ANCHORAGE TO SLAB IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS
STRUCTURAL PLAN - MAINTENANCE GARAGE
·
SCALE: 1/4" = 1'-0"
·
·
·
PRIME ALL SURFACES WITH TNEMEC SERIES 66, 161OR
205 EPOXY AT 3.0-5.0 DRY MILS.
PATCH ALL VOIDS AND FILL TO FLUSH WITH A MORTAR
MIX OF TNEMEC SERIES 237 AND SAND.
V-GROOVE THE CRACK 1/8” WIDE AND FILL TO FLUSH
SERIES 206 SUBFLEX.
BROADCAST FINE SAND INTO THE SERIES 206 TO KEEP
RECOAT WINDOW OPEN.
APPLY TNEMEC SERIES 206 TO ALL SURFACES AT 40-50
DRY MILS (35-45 SQ FT/GAL).
LIGHTLY SAND THE SERIES 206 TO DEGLOSS.
APPLY FINAL COAT (SEE AE-602)
C
BRICK STABLE FLOOR
1.
SURFACE PREPARATION:
CLEAN TO REMOVE ALL SOLUBLE SURFACE CONTAMINANTS.
REMOVE ALL UNSOUND CONCRETE. MECHANICALLY PREPARE TO
REMOVE ALL INSOLUBLE SURFACE CONTAMINANTS AND ACHIEVE
AN ICRI CSP 3. VERIFY MOISTURE LEVELS ARE IN ACCORDANCE
WITH MANUFACTURER'S INSTRUCTIONS.
·
26'-8"
D
COATING SYSTEM & CRACK REPAIR:
·
·
·
·
EL. 936.0
1'-6"
E
#4 HOOP @ 12" O.C.
2'-0"
(6) #4 BAR
6"
REQ'D GEOTEXTILE
FABRIC
17'-1"
REQ'D CRUSHED
AGGREGATE
S-101
SECTION - WEATHERPROOF STORAGE SLAB
SCALE: 1/4" = 1'-0"
F
SCALE: 1-1/2" = 1'-0"
STRUCTURAL PLAN - BRICK STABLE
F
17'-2"
2% SLOPE
14'-4"
REQ'D PCC SLAB
EXPANSION JOINT
E
·
·
PRIME ALL SURFACES WITH TNEMEC SERIES 66, 161OR
205 EPOXY AT 3.0-5.0 DRY MILS.
PATCH ALL VOIDS AND FILL TO FLUSH WITH A MORTAR
MIX OF TNEMEC SERIES 237 AND SAND.
V-GROOVE THE CRACK 1/8” WIDE AND FILL TO FLUSH
SERIES 206 SUBFLEX.
BROADCAST FINE SAND INTO THE SERIES 206 TO KEEP
RECOAT WINDOW OPEN.
APPLY TNEMEC SERIES 206 TO ALL SURFACES AT 40-50
DRY MILS (35-45 SQ FT/GAL).
LIGHTLY SAND THE SERIES 206 TO DEGLOSS.
APPLY TNEMEC SERIES 248 AT 2.0-3.0 DRY MILS.
The beginning of the document. Download the full file to read on.
Other documents in this bid
- Jessamine Camp Nelson Building
- Jessamine Camp Nelson Heavy
- Jessamine Camp Nelson Highway
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1