Preview
#
AD-150
1.
35'-2"
EXISTING ORIGINAL
REMOVE AND DISPOSE OF EXISTING SLIDING DOOR TRACK, BLOCKING,
AND ALL NON-HISTORIC HARDWARE IN THEIR ENTIRETY. PATCH
ADJACENT MASONRY SURFACES AS NEEDED.
2. REMOVE BARN DOORS. PREPARE FOR RESTORATION AND RELOCATION. SEE AE-152 FOR MORE DETAILS.
3. ENLARGE EXISTING 2'-10" MASONRY OPENING TO 3' 4" TO RECEIVE NEW
DOOR AND FRAME. INSTALL NEW STEEL LINTEL ABOVE AND CONTINUE
EXISTING SOLDIER COURSE ACROSS OPENING. INSTALL EXTERIOR BRICK
AND INTERIOR CMU AT EDGE OF NEW OPENING.
4. EXISTING EQUIPMENT/FURNISHINGS TO BE REMOVED BY CONTRACTOR
PRIOR TO BEGINNING CONSTRUCTION. CONTRACTOR IS TO
COORDINATE TEMPORARY STORAGE AND/OR DISPOSAL OF ALL EXISTING
ITEMS WITH CEMETERY SUPERINTENDENT PRIOR TO START OF WORK.
5. REMOVE AND DISPOSE OF EXISTING COUNTER AND CABINET, METAL
TOILET PARTITION, WATER CLOSET AND LAVATORY. SEE MECH. & ELEC. DRAWINGS FOR MORE INFORMATION.
6. REMOVE AND DISPOSE OF EXISTING DOOR AND FRAME.
7. REMOVE EXISTING WATER CLOSET, WALL MOUNTED LAVATORY, URINAL,
AND METAL TOILET PARTITION. SEE MECH. & ELEC. DWGS. FOR MORE
INFORMATION. PATCH EXISTING ADJACENT SURFACES TO REMAIN. 8. REMOVE AND DISPOSE OF EXISTING METAL LOCKERS.
9. REMOVE AND REPLACE EXISTING WATER HEATER ON CONCRETE BASE. 10. REMOVE EXISTING ALUMINUM STORM AND WOOD ENTRANCE DOOR.
REMOVE ANY STOPS RELATED TO THE STORM DOOR. RESTORE IN THEIR
ENTIRETY.
11. REMOVE AND DISPOSE OF EXISTING OVERHEAD GARAGE DOOR, TRACK
AND HARDWARE. PATCH ADJACENT SURFACES.
12. REMOVE EXISTING PULL-DOWN ATTIC STAIR ACCESS.
13. REMOVE EXISTING WALL BASE FOR INSTALLATION OF NEW BASE. 14. REMOVE IN-TACT ALL EXTERIOR TRIM TO INCLUDE CHIMNEY CROWN,. FASCIA, AND SOFFIT. PATCH ADJACENT SURFACES WITH LIKE MATERIALS.
15. REMOVE AND DISPOSE OF GUTTERS, DOWNSPOUTS, SUPPORTS, AND ALL
APPURTENANCES. PATCH ADJACENT SURFACES AS NEEDED. PREPARE
FOR NEW SCHEDULE GUTTERS AND DOWNSPOUTS. SEE PROPOSED
DRAWINGS FOR MORE DETAIL.
16. REMOVE AND DISPOSE OF ALL SHINGLES. ASSESS EXISTING SUBSTRATE. REMOVE AND DISPOSE OF DAMAGED ROOF SUBSTRATE AS NEEDED. PREPARE ADJACENT SURFACES FOR NEW SUBSTRATE AS NEEDED.
17. REMOVE AND DISPOSE OF ALL ROT. REPAIR DAMAGED RAFTERS AS
NEEDED. PATCH WITH LIKE MATERIALS. PRESERVE HISTORIC PROFILE OF
RAFTER TAILS.
18. REMOVE FLAKING PAINT ON RAFTERS, FASCIA, AND SOFFIT. SCRAPE, SAND, CLEAN, PREPARE FOR NEW SCHEDULED FINISH.
19. REMOVE AND DISPOSE OF EXISTING KITCHENETTE AND PLUMBING LINES.
20. REMOVE WALL AND EXISTING ADJACENT CONCRETE PADS. MAKE
SURFACES FLUSH WITH ADJACENT.
The beginning of the document. Download the full file to read on.
Other documents in this bid
- Jessamine Camp Nelson Building
- Jessamine Camp Nelson Heavy
- Jessamine Camp Nelson Highway
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- CNNC FCA Corrections CONS BD SPECIFICATIONS