GENERAL NOTES
B
B
A
FOR LIGHTNING PROTECTION GENERAL NOTES, SEE DRAWING
E-003.
A
1.
A
E-003
GROUNDING GRID
CONDUCTOR (TYP.)
G
G
LEGENDS
TW
C
C
B
E-003
GROUNDING CONDUCTOR
LIGHTNING CONDUCTOR
GROUNDING
TEST WELL
G
GROUND ROD
GROUNDING TEST WELL
TW
RUN DOWN CONDUCTOR DOWN AND
BOND TO BUILDING GROUND ROD. (TYP.)
RUN DOWN CONDUCTOR IN RIGID
CONDUIT 8' FROM GROUND UP AND
EXPOSED, MOUNTED ON WALL.
PANEL C
(LOCATED INSIDE
THE BUILDING)
AIR TERMINAL
A
LIGHTNING CONDUCTOR
RUN ALONG ROOF,
FASTENED EVERY
3 FEET MAX.
D
E-003
AIR TERMINAL (TYP.)
E
E-003
D
D
LIGHTNING
CONDUCTOR
"T" JOINT
CONNECTION (TYP.)
KEY PLAN
A
E
A
E
A
GROUND ROD
(TYP.)
TW
G
G
F
F
AREA OF WORK
NOT TO SCALE
ELECTRICAL GROUNDING AND LIGHTNING PROTECTION PLAN
SCALE : 1/2" = 1'-0"
SCALE : 1/2" = 1'-0"
Bid Set
SITE PLANS
WFS
STUTE
A
E
Walker Federal Services, LLC
N ATIONAL
C EMETERY
A DMINISTRATION
NGINEERING
7820B-162 Wormans Mill Road
Frederick, Maryland 21701
Creative Designs | Intelligent Solutions
ASTUTE ENGINEERING, PLLC.
Revisions
1945 OLD GALLOWS ROAD, STE 201, VIENNA, VA 22182
PH: (202) 400-2004 I WWW.ASTUTENG.COM
Date
1'
2'
4'
Drawing Title
Project Title
HISTORIC BRICK STABLE BLDG
ELECTRICAL GROUNDING AND
LIGHTNING PROTECTION PLAN
Correct FCA Deficiencies
Approved:
Building Number
HA2
Approved:
Location
CAMP NELSON NATIONAL CEMETERY
Date
JANUARY 7, 2026
Project No.
833CM3030
Checked
UB,HU
© COPYRIGHT 2022, Walker Federal Services, LLC
6'
Drawn
SV
DRAWING NO.
EN-204
Dwg. 130 Of 166
GENERAL NOTES
1.
B
E-003
FOR LIGHTNING PROTECTION GENERAL NOTES, SEE DRAWING
E-003.
A
E-003
GROUNDING GRID
CONDUCTOR (TYP.)
G
G
TW
A
A
GROUNDING
TEST WELL
RUN DOWN CONDUCTOR DOWN AND
BOND TO BUILDING GROUND ROD. (TYP.)
RUN DOWN CONDUCTOR IN RIGID
CONDUIT 8' FROM GROUND UP AND
EXPOSED, MOUNTED ON WALL.
D
E-003
B
A
LIGHTNING
CONDUCTOR
AIR TERMINAL (TYP.)
E
E-003
A
A
B
"T" JOINT
CONNECTION (TYP.)
PANEL D
(LOCATED INSIDE
THE BUILDING)
LIGHTNING CONDUCTOR
RUN ALONG ROOF,
FASTENED EVERY
3 FEET MAX.
GROUND ROD
(TYP.)
TW
G
G
C
C
LEGENDS
GROUNDING CONDUCTOR
LIGHTNING CONDUCTOR
G
ELECTRICAL GROUNDING AND LIGHTNING PROTECTION PLAN
GROUND ROD
GROUNDING TEST WELL
TW
SCALE : 1/4" = 1'-0"
AIR TERMINAL
D
D
A
E
E
KEY PLAN
F
F
AREA OF WORK
SCALE : 1/4" = 1'-0"
Bid Set
WFS
STUTE
A
E
Walker Federal Services, LLC
N ATIONAL
C EMETERY
A DMINISTRATION
NGINEERING
7820B-162 Wormans Mill Road
Frederick, Maryland 21701
Creative Designs | Intelligent Solutions
ASTUTE ENGINEERING, PLLC.
Revisions
1945 OLD GALLOWS ROAD, STE 201, VIENNA, VA 22182
PH: (202) 400-2004 I WWW.ASTUTENG.COM
Date
2'
4'
8'
Drawing Title
Project Title
MAINTENANCE STORAGE BLDG
The beginning of the document. Download the full file to read on.
Other documents in this bid
- Jessamine Camp Nelson Building
- Jessamine Camp Nelson Heavy
- Jessamine Camp Nelson Highway
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- CNNC FCA Corrections CONS BD SPECIFICATIONS