Amendment 4- - BID - from - - BID - SET
Updated
A PDF document (1.8 MB) attached to Camp Nelson National Cemetery, KY 833CM3030 – Correct FCA Deficiencies, from the Department of Veterans Affairs. Due Dec 7, 2026, 9:00 AM (UTC-5).
File name: Amendment 4-833CM3030 - BID - AE-110 from 20260422 - 833CM3030 - BID - SET.pdf
The full file is for paid members, or buy this bid alone.
Preview
LEGEND
EXISTING FLOOR DRAIN
FD
NEW FIRE EXTINGUISHER
CORNER GUARD. SALVAGE FOR REUSE.
G.C. TO PROVIDE NEW TO MATCH AS
NEEDED.
CG-1
ELECTRIC PANEL. SEE ELECTRIC
DRAWINGS FOR MORE INFORMATION.
DOOR TAG
MULTI PURPOSE
UTILITIES
IT ROOM
PUBLIC
MALE
A-100
A-102
A-101
A-103
BW-117M
EXISTING FLOOR
FINISH TO REMAIN.
EXISTING FLOOR
FINISH TO REMAIN.
EXISTING FLOOR
FINISH TO REMAIN.
EXISTING FLOOR
FINISH TO REMAIN.
PATCH FLOOR
FINISH WITH LIKE
MATERIALS.
EXISTING FLOOR
FINISH TO REMAIN.
VESTIBULE
PUBLIC
FEMALE
A-104
E
A
A
EXISTING DOOR TO REMAIN
EXISTING FLOOR FINISH TO REMAIN. PATCH
FLOOR FINISH WITH LIKE MATERIALS.
FEATHER EDGES OF EXISTING RESTROOM
EXPANSION AREAS. APPLY NEW EPOXY
SYSTEM TO NEW AREAS. ENSURE
FEATHERED TRANSITION ZONES ARE
SMOOTH AND RECTILINEAR.
EXISTING DOOR TO BE RELOCATED
R
NEW EPOXY FLOORING
E
A
6'-9 1/2"
1'-6"
15'-0"
E
E
B
B
E
CG-1
CG-1
CG-1
CG-1 FD
FD
6'-8"
WATER
HEATER
1'-7 1/4"
8'-7"
8'-7"
SEE AE-114 FOR ENLARGED PLAN
AND INTERIOR ELEVATIONS
2'-6"
FE ELEC
PANEL
6'-9 1/2"
FD
TS-1
4'-8"
C
±5'-0"
EXISTING OPENING
EXIST.
STR. COL.
FOR ROOF
3'-11"
3'-11"
4'-8"
AE-113
CG-1
AE-115
R
4'-0"
C
AE-113
R
FD
CG-1
FD
2'-2"
5'-2"
NEW OPENING
B.1
2.
FOR FLOOR FINISHES REFER TO AE-600 SERIES SCHEDULE OF FINISHES.
3.
PATCH CEILING WITH SAME MATERIALS.
4.
ALL WALLS TO MATCH EXISTING ADJACENT, UNLESS NOTED OTHERWISE.
1.
REFER TO FLOOR PLAN AND SCHEDULES FOR ADDITIONAL FINISH INFORMATION.
2.
LOCATE CHANGES IN FLOOR FINISH MATERIAL UNDER CENTERLINE OF CLOSED DOOR
UNLESS OTHERWISE INDICATED.
3.
ALL CEILING MATERIAL MUST HAVE CLASS "A" FIRE RATING.
4.
PAINT ALL NON STAINLESS STEEL FIRE EXTINGUISHER CABINETS, VENTS, GRILLES,
PLUG STRIP, ELECTRICAL PANEL BOARDS, DIFFUSERS, AND EXPOSED DUCTS TO
MATCH ADJACENT SURFACE FINISH.
5'-9"
V.I.F
TYPICAL INTERIOR FINISHES
BOOT
WASH
STAFF
TOILET
A-106
FOR GENERAL SYMBOLS, MATERIALS AND ABBREVIATIONS, SEE A-001 THROUGH A-003.
EXISTING CONCRETE
PATH
15'-2 1/2"
1.
ALL WALLS TO BE PAINTED TO MATCH EXISTING ADJACENT, UNO.
2.
ALL VANITY TOPS IN PUBLIC AND STAFF BATHROOMS TO BE NATURAL STONE, UNO.
3.
ALL WALL APPLIED CERAMIC TILE TO MATCH EXISTING ADJACENT, UNO.
4.
CORRIDOR FLOOR TO BE POLISHED CONCRETE. PUBLIC RESTROOM FLOORS TO
REMAIN EPOXY.
FINISHES
EYE
WASH
ALL NEW FINISHES TO MATCH EXISTING ADJACENT. REFER TO SCHEDULE OF FINISHES.
PRESSURE
WASHER
FLOORING AND
BASE, SAME AS
CORRIDOR.
27'-8"
INSULATE ALL PIPES BEHIND DRYWALL
PROVIDE NEW TYPE-X DRYWALL
EDGE OF MEZZANINE ABOVE
The beginning of the document. Download the full file to read on.
Other documents in this bid
- Jessamine Camp Nelson Building
- Jessamine Camp Nelson Heavy
- Jessamine Camp Nelson Highway
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1