LEGEND
KEYNOTES
PAVEMENT/AGGREGATE SURFACE REMOVAL
01 SELECTIVELY DEMOLISH EX. PAVEMENT (SEE NOTE 5)
APPROX. LIMITS OF LEACH FIELD REMOVAL
(SEE NOTE 1)
02 BOLLARD TO BE REMOVED
EXISTING SANITARY SEWER (TO BE REMOVED)
TANK TO BE REMOVED, LEGALLY DISPOSE OF WASTE
03 FUEL
FUEL AND TANK
SELECTIVELY REMOVE EXISTING SEPTIC LEACH FIELD TILES,
SEPTIC TANK TO REMAIN, SANITARY PIPING TO BE REMOVED,
A
05 APPROX. PIPE DEPTH 934.41 (SEE NOTE 3)
A
04 PIPING, AND SOIL FOR POINT REPAIR (SEE NOTE 2)
06 SEPTIC DISTRIBUTION BOX TO REMAIN (SEE NOTE 3)
07 REMOVE EX. AGGREGATE SURFACE
08 DEMOLISH EX. LEAN-TO SHELTER
DEMOLISH EX. DRAIN INLET BASIN.
EMPLOY LICENSED ARBORIST, REMOVE TREES AND GRIND
10 STUMPS (SEE NOTE 6)
0"
'-1
'-1
09 SALVAGE HISTORIC GRATE (SEE NOTE 4)
1"
11 EXISTING AGGREGATE DRAIN BED (TO REMAIN)
B
B
12 DEMOLISH EXISTING SPOILS STORAGE SHELTER
REMOVE, STORE, & PROTECT PROPANE STORAGE TANK
13 (SEE NOTE 7)
14 REMOVE, STORE, & PROTECT AC CONDENSER (SEE NOTE 7)
NOTES
1.
ALL WORK ON SEPTIC SYSTEM SHALL BE A PERFORMED
CERTIFIED ONSITE SEWAGE SYSTEM INSTALLER, LICENSED IN
THE STATE OF KENTUCKY.
2.
BOUNDS OF EX. LEACH FIELD AND LOCATION OF LATERALS ARE
APPROXIMATE AND SHALL BE FIELD VERIFIED BY THE
CONTRACTOR PRIOR TO DEMO. PRESERVE EXISTING ADJACENT
LATERAL TILES.
3.
LOCATION OF SEPTIC TANK & DISTRIBUTION BOX ARE
APPROXIMATE AND SHALL BE FIELD VERIFIED BY CONTRACTOR
PRIOR TO PIPE REMOVAL. SANITARY SERVICE SHALL BE
PROVIDED AT ALL TIMES. POSITIVELY LOCATE, IDENTIFY, AND
PROTECT EXISTING CROSSING UTILITES TO REMAIN.
4.
REMOVE, STORE, AND PROTECT EXISTING DRAIN GRATE AND
COLLAR IN THEIR ENTIRETY. RESTORE DRAIN GRATE AND
PREPARE FOR REINSTALLATION IN NEW CONCRETE PAVEMENT.
SEE AE-002 FOR CAST IRON CONSERVATION NOTES.
5.
NEAT VERTICAL SAWCUT IS REQUIRED BETWEEN PAVEMENT TO
BE REMOVED AND PAVEMENT TO REMAIN.
6.
EXERCISE EXTREME CAUTION TO AVOID DAMAGE TO SEPTIC
LATERAL TILES. DO NOT OPERATE EQUIPMENT OVER LEACH
FIELD.
C
DEMOLITION PLAN - MAINTENANCE AREA
SCALE: 1" = 20'-0"
DEMOLITION PLAN - CEMETERY ROAD
SCALE: 1" = 10'-0"
12'-5
"
D
7.
C
D
"
42'-2
KEY
E
E
42'-2"
13'-9"
DEMOLITION PLAN - CEMETERY ROAD
F
F
SCALE: 1" = 10'-0"
DEMOLITION PLAN - SPOILS AREA
NOT TO SCALE
SCALE: 1" = 40'-0"
Bid Set
WFS
Revisions
N ATIONAL
C EMETERY
A DMINISTRATION
PRINCIPAL
Walker Federal Services, LLC
Engineering
7820B-162 Wormans Mill Road
Frederick, Maryland 21701
128 NORTHPARK BLVD.,
COVINGTON, LA 70433
Drawing Title
Project Title
SITE DEMOLITION PLAN
Correct FCA Deficiencies
833CM3030
Approved:
Building Number
Approved:
The beginning of the document. Download the full file to read on.
Other documents in this bid
- Jessamine Camp Nelson Building
- Jessamine Camp Nelson Heavy
- Jessamine Camp Nelson Highway
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1