PLUMBING NOTES
DIVISION 22 PLUMBING
22-0000 GENERAL REQUIREMENTS
SCOPE AND DRAWINGS
1. CONTRACTOR SHALL REFER TO ALL DRAWINGS AND SPECIFICATIONS IN THIS PACKAGE SUCH AS ARCHITECTURAL, STRUCTURAL, ELECTRICAL, AND PLUMBING. FULLY COORDINATE WITH ALL OTHER TRADES, OWNER, AND ARCHITECT REQUIREMENTS. ALL OF THE ABOVE-MENTIONED DRAWINGS AND SPECIFICATIONS ARE CONSIDERED A PART OF THE CONTRACT DOCUMENTS.
A
2. CONTRACTOR IS TO INSPECT THE SITE BEFORE SUBMITTING BID AND MAKE ALLOWANCES FOR ALL VISIBLE, SPECIFIED OR REASONABLY ANTICIPATED FIELD CONDITIONS. SIGNIFICANT DISCREPANCIES FROM THE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT, ARE TO BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER, ARCHITECT AND ENGINEER IN WRITING PRIOR TO SUBMITTAL OF BID.
3. THE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND INDICATE THE GENERAL LOCATION AND INTENT OF THE SYSTEMS. AS SUCH DRAWINGS DO NOT INDICATE EVERY FITTING, ELBOW, OFFSET, VALVE, AND OTHER COMPONENTS NECESSARY TO INSURE PROPER INSTALLATION OF A WORKING SYSTEM. CONTRACTOR SHALL PROVIDE ALL NECESSARY FITTINGS, ACCESSORIES, AND AUXILIARY ITEMS TO INSTALL THE SYSTEM AS DIAGRAMMED.
B
Ø OR DIA
DIAMETER
AFF
ABOVE FINISHED FLOOR
AP
ACCESS PANEL
5. ENGINEER HAS NOT FUNCTIONALLY TESTED EXISTING EQUIPMENT. WHERE EXISTING EQUIPMENT IS TO BE REUSED, CONTRACTOR SHALL ALLOW FOR REASONABLE CHECKING, ADJUSTMENT AND MINOR
REPAIR TO RESTORE FULL FUNCTION. WORK WHICH IS REQUIRED AND WHICH IS BEYOND THAT
DESCRIBED ABOVE OR ON THE PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER, ARCHITECT AND ENGINEER.
BT
BATHTUB
BLDG
BUILDING
CLG
CEILING
CO
CLEAN OUT
CW
COLD WATER
1. THE CONTRACTOR SHALL PROVIDE FOR HIS OWN CLEAN UP, REMOVAL AND DISPOSAL OF DAILY TRASH. THE CONTRACTOR SHALL KEEP CLEAN AND MAINTAIN EACH AREA FOR USE AFTER WORK IN THAT AREA IS COMPLETE.
DEG
DEGREES
DF
DRINKING FOUNTAIN
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF HIS OWN WORK, MATERIALS, AND OTHER BELONGINGS FROM DAMAGE.
DFU
DAINAGE FIXTURE UNITS
DIA
DIAMETER
DN
DOWN
DW
DISHWASHER
DWH
DOMESTIC WATER HEATER
ETR
EXISTING TO REMAIN
EWH
ELECTRIC WATER HEATER
EWS
EYE WASH STATION
EX
EXISTING
F
FAHRENHEIT
FCO
FLOOR CLEANOUT
FD
FLOOR DRAIN
FS
FLOOR SINK
G
GAS
GAL
GALLONS
GPM
GALLONS PER MINUTE
GWH
GAS WATER HEATER
HB
HOSE BIB
HP
HORSE POWER
HS
HAND SINK
HW
HOT WATER
HWR
HOT WATER RECIRCULATION
I.E.
INVERT ELEVATION
JAN
JANITOR
LAV
LAVATORY
LP
LIQUID PROPANE
MAX
MAXIMUM
MBH
1000 BTU/HR
MFR
MANUFACTURER
MIN
MINIMUM
MS
MOP SINK
NIC
NOT IN CONTRACT
PSI
POUNDS PER SQUARE INCH
PVC
POLYVINYL CHLORIDE
PW
POWER WASHER
RH
RELATIVE HUMIDITY
RX
The beginning of the document. Download the full file to read on.
Other documents in this bid
- Jessamine Camp Nelson Building
- Jessamine Camp Nelson Heavy
- Jessamine Camp Nelson Highway
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1
- From CNNC FCA Corrections CONS BD DRAWINGS VOL 1