Report Summary
General
Williiam Henderson LLC, in cooperation with SDV Services Inc., provided electrical testing and maintenance services at the Veterans Affairs Medical Center Bowling Division in Lexington, Kentucky on November 2023 to February 2024 under contract number 36C2493P0897. All services were conducted in accordance with contract specifications, industry standards, NFPA .
This report consists of the following:
Section 1

Electrical Testing and Maintenance Report Summary

Section 2

Publications/Exhibits

Section 3

Electrical Test Records

Section 4

Individual Thermographic Test Records

Section 5

Licenses, Certificates, Specialized Tools & Equipment

The types of equipment tested during this testing session included: Medium Voltage Circuit Breakers
Medium Voltage Switches
Medium Voltage Network Protectors
Medium Voltage Oil- and Dry-Type Transformers
Low Voltage Switchboards and Circuit Breakers (select areas) Automatic Transfer Switches
Motor Control Centers
Electrical Panels
item and type.

1|P a g e

Thermographic Inspection (Infrared)
In addition to regular testing procedures, infrared scan procedures were used wherever possible to determine serviceability and reliability of the equipment inspected to include panelboards. The infrared services were conducted using a FLIR T440 thermal imaging camera. While infrared technology can be an invaluable tool in predictive maintenance, it is not without limitations. Reflectivity, background, material emissivity and ambient temperature are among many factors that can influence thermal readings. As a result, reported temperature readings outlined in this report should not be viewed or used in terms of absolute temperature readings. Instead, the readings should be viewed in terms of trends and relationships with other equipment components or like materials.
Supplemental tests were performed wherever possible and on an as-needed basis. These tests consisted of recording circuit loads and conducting Voltage Drop Tests. Circuit loads were monitored to assist in identifying potential phase imbalances or overload conditions. Voltage Drop tests were conducted to determine potential contact resistance issues. Both tests are extremely valuable in helping to determine potential sources of temperature variances. The Individual Thermographic Report section of this report provides a report on each piece of equipment with a deficiency to include among other things: